案例廠在製造半導體使用的清洗劑以異丙醇為主,異丙醇屬於低沸點揮發性有機氣體,對人體健康及環境造成潛在的威脅。案例廠在評估各種處理技術優缺點後,選擇活性碳流體化床連續吸脫附後焚化(本文稱為活性碳流體化床)技術控制製程排氣污染。案例廠活性碳流體化床係由吸附塔、脫附塔、氧化塔及預熱塔等設備所組成,吸附異丙醇後的活性碳經由脫附塔脫附處理後,回流至吸附塔使用;脫附塔脫附的排氣則經由氧化塔高溫燃燒。
本文控制氧化塔燃燒溫度在850 ℃至600 ℃區間,每個階段往下調整50 ℃,尋找可以達到出口排放量在0.3 kg/hr (法定值為0.6 kg/hr)以下,排氣處理削減率達90%以上的排氣入口端異丙醇(以CH4表示)濃度上限。在前述要求下,當氧化塔燃燒溫度階段調控在850、800、750、700 ℃,可處理排氣入口端異丙醇濃度上限值分別為275、232、210、185 ppm。然而,當氧化塔燃燒溫度為650及600 ℃時,製程排氣入口端濃度需以166及147 ppm為排氣入口端處理上限值,這兩個燃燒溫度雖然出口排放量符合設定值,但排氣處理削減率未符合規劃目標。
案例廠108年度製程排氣入口端異丙醇濃度分布頻率最高為150至200 ppm間,次高為200至250 ppm間;累積頻率分布中位數為180.5 ppm。109年2月案例廠設定氧化塔最適燃燒溫度為800℃,當製程排氣入口端異丙醇濃度最高為225 ppm時,仍可符合排氣出口排放量在0.3 kg/hr下,排氣處理削減率達90%以上的條件。在熱能再利用方面,案例廠氧化塔燃燒需電能成本約136萬元/年,但燃燒可提供預熱塔及脫附塔熱能191萬元/年產值。
The studied factory used isopropanol as a major cleaning agent in the semiconductor manufacturing process. Isopropanol is a volatile organic gas with a low-boiling point and poses potential threats to human health and the environment. After evaluating the advantages and disadvantages of various treatment technologies, the studied factory chose an activated carbon fluidized bed with continuous adsorption and desorption followed by combustion technology (herein referred to as activated carbon fluidized bed) for controlling process exhaust pollution. The activated carbon fluidized bed of the studied factory is composed of an adsorption tower, desorption tower, oxidation tower, and preheating tower. The activated carbon after isopropanol adsorption is desorbed by the desorption tower and then returned to the adsorption tower for reusing; the exhaust gas desorbed by the desorption tower is combusted at the oxidation tower with high temperature.
This study seeks the upper limit of isopropanol (expressed in CH4) concentration at the exhaust inlet for a step of 50 ℃ in the range of 850 to 600 ℃ in oxidation tower, which meets 0.3 kg/hr (the legal value is 0.6 kg/hr) and over 90% reduction rate of the exhaust at the outlet. Under the previous requirements, the upper limit of isopropanol concentrations at the exhaust inlet from stepwise temperature adjustment in the oxidation tower for 850, 800, 750, and 700 ℃ were 275, 232, 210, and 185 ppm, respectively. However, the upper limit of isopropanol concentrations at the exhaust inlet was 166 and 147 ppm when the combustion temperatures of the oxidation tower were 650 and 600 ℃, respectively. Although these two combustion temperatures met exhaust requirements, the reduction rate of exhaust did not reach the planning objective.
The highest frequency distribution of isopropanol concentration in the exhaust inlet was between 150 and 200 ppm, the second-highest one was ranged from 200 and 250 ppm, and the median value of cumulative frequency distribution was 180.5 ppm for the studied factory in 2019. In February 2020, the studied factory determined to set the combustion temperature of the oxidation tower at 800 °C. Based on the monitored data, the exhaust at the outlet could still meet the exhaust emission requirements at 0.3 kg/hr and over 90% reduction rate when the isopropanol concentration at the exhaust inlet reached as high as 225 ppm. As to heat energy reuse, this study assessed that the electricity cost of the oxidation tower was about NT$1.36 million/yr in contrast to about NT$1.909 million/yr worth of the heat produced from the combustion and provided for preheating and desorption towers.
[1] 王瑞崇,應用 CMB 受體模式解析工業區揮發性有機物污染源貢獻量,朝陽科技大學環境工程與管理系碩士論文,民國101年7月25日。
[2] 異丙醇安全資料表,李長榮化學工業股份有限公司,民國107年12月3日。
[3] 108年空氣品質監測年報,行政院環境保護署公布,民國109年3月17日。
[4] 半導體製造業空氣污染管制及排放標準,行政院環境保護署修正發佈規定,民國91年10月16日。
[5] 公私場所固定污染源空氣污染物排放量申報管理辦法,行政院環境保護署修正發佈規定,民國92年8月6日。
[6] 公私場所固定污染源申報空氣污染防制費之揮發性有機物之行業製程排放係數、操作單元(含設備元件)排放係數、控制效率及其他計量規定,行政院環境保護署修正發佈規定,民國105年7月25日。
[7] 周明顯,「光電半導體 VOCs 處理成本分析及效益分析」,取自http://ebooks.lib.ntu.edu.tw/1_file/moeaidb/012835/2004081304B.pdf。
[8] 撰稿者: 翁興中、劉妙生、蘇艾、劉聖幸,高科技電子業揮發性有機物污染管制理論與實務,中華技術學院、興普科技股份有限公司、元智大學。
[9]莊錦烽、葉國棟、李素梅、許健毅,「高科技VOC管理與控制技術研析」,工業污染防治第106期,民國97年。
[10] 撰稿者:白醺綾教授、盧重興教授、張國財博士、曾映棠、黃欣惠,操作績效自我評估管理制度手冊-活性碳吸附塔,補助單位:科學工業園區管理局、執行單位:國立交通大學環境工程研究所、國立中興大學環境工程學系。
[11] 朱小蓉,流體化床吸附系統於光電業VOC排氣之處理應用,華懋科技股份有限公司。
[12] BAC活性碳資料,日本吳羽公司DM。
[13] 株式会社吳羽,BAC的特点,取自https://www.kureha.co.jp/cn/business/material/bac.html。
[14] 國家教育研究院,活性碳-環境科學大辭典,2002年2月,取自http://terms.naer.edu.tw/detail/1318008/?index=2966。
[15]排放管道中總碳氫化合物及非甲烷總碳氫化合物含量自動檢測方法-線上火燄離子化偵測法(NIEA A723.73B) ,行政院環境保護署公告,109年7月15日。
[16]固定污染源空氣污染物連續自動監測設施管理辦法,行政院環境保護署修正發佈規定,民國108年4月12日。
[17] 薛聖翰,利用熱重分析法探討含硫活性碳之氣化汞吸附及脱附研究,國立中山大學環境工程研究所碩士論文,民國97年8月。
[18] 林文川,製程 VOCs 排氣之收集與處理,工業污染防治第110期 (July 2009) 75。
[19] 工業局製造業能源管理系統示範輔導人員訓練專班熱力系統節能量測介紹,取自file:///D:/Users/dio_kao/Downloads/41f02d0b-2f6a-472b-85a7-3104ac65e601%20(1).pdf。
[20] 量測資訊網,取自http://www.measuring.org.tw/knowledge/knowledge_detail.asp?id=8。
[21] 排放管道中醇類檢測方法-丙二醇吸收/氣相層析火焰離子偵測法 (NIEA A733.71B) ,行政院環境保護署公告,98年7月14日。
[22] 台灣電力公司,取自https://www.taipower.com.tw/tc/page.aspx?mid=5523&cid=2870&cchk=9b81db85-9eee-460d-9d04-c52b59140d7e。
[23]吉能科技股份有限公司,取自http://www.gers.com.tw/?voc%E8%99%95%E7%90%86%E6%8A%80%E8%A1%93,6。