| 研究生: |
胡君陽 Jiun-Yang Hu |
|---|---|
| 論文名稱: |
改善運動中手腕型PPG心率測量 Improvement of Wrist-worn Photoplethysmographic Heart Rate Monitoring during Physical Activities |
| 指導教授: |
蔡章仁
Jang-Zern Tsai |
| 口試委員: | |
| 學位類別: |
碩士 Master |
| 系所名稱: |
資訊電機學院 - 電機工程學系 Department of Electrical Engineering |
| 論文出版年: | 2017 |
| 畢業學年度: | 105 |
| 語文別: | 中文 |
| 論文頁數: | 103 |
| 中文關鍵詞: | 光體積描記法 、心率監測 、穿戴裝置 、動作偽影 |
| 外文關鍵詞: | Photoplethysmography, Heart Rate Monitoring, Wearable Device, Motion Artifact |
| 相關次數: | 點閱:11 下載:0 |
| 分享至: |
| 查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
基於光體積描記法(Photoplethysmography, PPG)的手腕心率監測,使用者在靜態中測量會有較高的準確性,但是在動態中測量則會有較大的誤差。由於PPG訊號會受到手腕動作所引起的偽影雜訊干擾,影響心率測量的準確度。為了改善這個在動態中測量心率的問題,本研究提出一個方法由,來達到抑制動作偽影以及提高心率估計準確度的目的。這方法由兩階段的策略組成。第一階段分析由PPG訊號與三軸加速度訊號所得出的頻譜,利用所提出的抑制動作偽影方法識別出PPG頻譜上的偽影區間並抑制其偽影干擾。第二階段基於短時間內心率的連續性,利用前一刻的心率縮小心率估計的搜尋範圍,提高動態中PPG心率估計的準確性。12位受測者的心率估計誤差平均值為2.57 BPM,有效減少運動過程中所引起的心率測量上的失真。
While the accuracy of heart rate monitoring using photoplethysmography (PPG) is quite acceptable when the person stays still, it could deteriorate during physical activities. The motion artifacts due to hand movements in the received PPG signal interfere with the heart rate detection. In this study, we propose a two-stage strategy to reject the motion artifacts and improve the accuracy of heart rate detection. At the first stage, the frequency spectrum of the received PPG signal is analyzed and the spectral components owing to the motion artifacts are identified and deleted by spectral subtraction. To detect the frequency spectrum of the motion signal, three-axis accelerometers are used. At the second stage, the heart rate is estimated on the basis of the spectral peaks of next moment and the tracking information of previous heart rates. This tracking estimation method has considerably improved the accuracy of PPG heart rate monitoring during physical activities. Experiments with 12 test subjects resulted in an average heart rate error of 2.57 BPM.
[1] ACSM. 健康產業趨勢. Available: http://journals.lww.com/acsm-healthfitness/Fulltext/2016/11000/WORLDWIDE_SURVEY_OF_FITNESS_TRENDS_FOR_2017.6.as
[2] ERICSSON. (2016). 穿戴式裝置未來發展. Available: https://www.ericsson.com/thinkingahead/consumerlab/consumer-insights/wearable-technology-and-the-internet-of-things
[3] 衛生福利部國民健康署. 運動強度. Available: http://obesity.hpa.gov.tw/TC/intensity.aspx
[4] J. Allen, "Photoplethysmography and its application in clinical physiological
measurement," Physiological Measurement, vol. 28, pp. R1–R39, Feb 20 2007.
[5] J. H. A. Kamal, G. Irving, and A. Mearns, "Skin photoplethysmographya review," Computer methods and programs in biomedicine, vol. 28, no. 4, pp. 257–269, 1989.
[6] SeungMin Lee, HyunSoon Shin, ChanYoung Hahm, "Effective PPG Sensor Placement for Reflected Red and Green light, and Infrared Wristband-type Photoplethysmography," Advanced Communication Technology (ICACT), 2016 18th International Conference on, pp. 556-558, March 2016.
[7] Alrick B. Hertzman, "The blood supply of various skin areas as estimated by the Photoelectric Plethysmograph," From the Department of Physiology, St. Louis University School of Medicine,St. Louis, Missouri, 1938.
[8] Y. Maeda, M. Sekine, T. Tamura, A. Moriya, T. Suzuki, and K. Kameyama, "Comparison of reflected green light and infrared photoplethysmography," in 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2008, pp. 2270-2272.
[9] B. Desai and U. Chaskar, "Comparison of optical sensors for non-invasive hemoglobin measurement," in 2016 International Conference on Electrical, Electronics, and Optimization Techniques (ICEEOT), 2016, pp. 2211-2214.
[10] T. Tamura,Y. Maeda , M. Sekine and M. Yoshida "Wearable Photoplethysmographic Sensors—Past and Present," MDPI — Electronics, 2014,3,282-302.
[11] T. Shimazaki, S. Hara, H. Okuhata, H. Nakamura, and T. Kawabata, "Cancellation of motion artifact induced by exercise for PPG-based heart rate sensing," in 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2014, pp. 3216-3219.
[12] H. Han, M. J. Kim, and J. Kim, "Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography," in 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2007, pp. 1538-1541.
[13] J. H. B. Lee, H. J. Baek, J. H. Shin, K. S. Park, and W. J. Yi, "Improved elimination of motion artifacts from a photoplethysmographic signal using a kalman smoother with simultaneous accelerometry," Physiological measurement, vol. vol. 31, no. 12, pp. 1585–1603, 2010.
[14] M. Raghuram, K. V. Madhav, E. H. Krishna, and K. A. Reddy, "Evaluation of wavelets for reduction of motion artifacts in photoplethysmographic signals," in 10th International Conference on Information Science, Signal Processing and their Applications (ISSPA 2010), 2010, pp. 460-463.
[15] M. R. Ram, K. V. Madhav, E. H. Krishna, N. R. Komalla, and K. A. Reddy, "A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter," IEEE Transactions on Instrumentation and Measurement, vol. 61, pp. 1445-1457, 2012.
[16] B. S. Kim and S. K. Yoo, "Motion artifact reduction in photoplethysmography using independent component analysis," IEEE Transactions on Biomedical Engineering, vol. 53, pp. 566-568, 2006.
[17] H. Fukushima, H. Kawanaka, M. S. Bhuiyan, and K. Oguri, "Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running," in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2012, pp. 2901-2904.
[18] Z. Zhang, Z. Pi, and B. Liu, "TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise," IEEE Transactions on Biomedical Engineering, vol. 62, pp. 522-531, 2015.
[19] Z. Zhang, "Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction," IEEE Transactions on Biomedical Engineering, vol. 62, pp. 1902-1910, 2015.
[20] C. Zong and R. Jafari, "Robust heart rate estimation using wrist-based PPG signals in the presence of intense physical activities," in 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2015, pp. 8078-8082.
[21] J. G. a. H. Hall, Textbook of medical physiology: Saunders/Elsevier, 2011.
[22] F.Ganong(1996), 甘龍醫用生理學下册 (Review of medical physiology): 藝軒圖書出版社, 1996.
[23] 林正常, 運動生理學: 師大書苑, 2011.
[24] A. A. Atkielski). (2007, 13 January). Wikimedia Commons, Available : . https://en.wikipedia.org/wiki/Biomedical_engineering,
[25] 陸恩祥、夏緒芬、楊曉英、項明慧, 心電圖臨床實習圖譜: 遼寧科技技術出版社, 2002.
[26] (2017). 心電圖. Available: https://zh.wikipedia.org/wiki/%E5%BF%83%E7%94%B5%E5%9B%BE#cite_note-25
[27] H. v. Helvete. (4 March 2014). Wikimedia Commons,Normal ECG/EKG complex with labels. Available: https://commons.wikimedia.org/wiki/File:EKG_Complex_en.svg
[28] J. H. T. Ruegheimer. (2015). 反射光脈搏測量原理. Available: http://archive.eettaiwan.com/www.eettaiwan.com/ART_8800711378_480502_TA_57e1bee9.HTM
[29] 呂宗憲,林筱莉,陳智傑, ECG與PPG信號之相關性研究. 台中市: 逢甲大學, 2006.
[30] F. Z. John V. G., Peter C. F., "Multi-photon excitation in uncaging the small molecule bioregulator nitric oxide," vol. 371, 28 July 2013.
[31] M. Dadafshar. (2014). Accelerometer and Gyroscopes Sensors: Operation, Sensing, and Applications. Available: https://www.maximintegrated.com/en/app-notes/index.mvp/id/5830
[32] 曾煜棋、林政寬、林致宇、潘孟鉉, 無線網路:通訊協定、感測網路、射頻技術與應用服務: 碁峰出版社, 2011.
[33] 周品言, "藍芽通訊傳輸延遲之研究," 國立臺灣科技大學 資訊工程學系, 2014.
[34] (2017). 庫利-圖基快速傅立葉變換算法. Available: https://zh.wikipedia.org/wiki/%E5%BA%93%E5%88%A9%EF%BC%8D%E5%9B%BE%E5%9F%BA%E5%BF%AB%E9%80%9F%E5%82%85%E9%87%8C%E5%8F%B6%E5%8F%98%E6%8D%A2%E7%AE%97%E6%B3%95
[35] 劉仲舫, "整合物聯網技術應用於團體運動訓練 Integrating Internet of Things Technology for Group Fitness Training," 國立中央大學 電機工程學系, 2016.
[36] Wikipedia contributors. "藍牙"維基百科,自由的百科全書,26 May 2016,
Available: https://zh.wikipedia.org/zh-tw/%E8%97%8D%E7%89%99。