  • 在本論文中,主要利用閃爍之心理物理學實驗方式量化人眼在不同波長、不同視角時之眼內散射強度並分析其實驗結果。首先測試了實驗之可重複性,接著量測了分別為450、555、610、670四種波長之眩光源,以及與視軸夾5、10、15、20、30、45度眩光源之眼內散射程度,受試者一共有七位,年齡在23至25歲之間,左右眼皆有作測量;實驗結果顯示,眼內散射之強烈程度在短波長較高,隨著波長增加而有減少的現象,接著在長波長又再度增加;為分析趨勢,我們建立了一個數學模型,模型中包含Rayleigh Scatter、Mie Scatter、視網膜基底反射以及老化影響等四種不同因素對眼內散射之影響,並以這四種因素在實驗結果中所佔之百分比做分析;最後,將實驗結果與常見的失能眩光公式作比較,發現我們的實驗結果與CIE失能眩光公式形式較為匹配。


    The main content of this research includes a quantification experiment for intraocular straylight from glare sources with varied wavelengths and glare angles. This study first confirmed the repeatability of this setup by repeating the experimental process for 4 times. Then the experiment was performed to measure the straylight parameters from 7 subjects in the following conditions: four glare source wavelengths, 450, 555, 610 and 670 nm, and six glare angles, 5, 10, 15, 20, 30 and 45 degrees. The result showed the stronger scatter at short wavelength of glare, the decay with the increment of the wavelength value, and finally a boost at long wavelength value. The explanation for the results in the discussion revealed a coupled model of Rayleigh scatter effect, Mie scatter effect, fundus reflection and aging effect. At last, the comparison between the results with well-known disability glare equation showed a good match with the CIE disability glare equation.

    摘要 i Abstract ii 致謝 iii 目錄 v 圖索引 ix 表索引 xii 第一章 緒論 1 1-1 研究動機 1 1-2 人類眼球構造簡介 2 1-3 眼內散射相關研究發展史 3 1-4 論文大綱 10 第二章 背景知識及相關研究 11 2-1 光度計量單位 11 2-2 散射 13 2-3 眩光介紹 14 2-3-1 失能眩光 15 2-3 p分數 19 2-4 決定係數 21 2-5 強迫二選一法 22 第三章 眼內散射實驗的建立 23 3-1 實驗方法 23 3-2 實驗原理 25 3-2-1 眼內散射指數S值 25 3-2-2 S值定義投影片輝度 26 3-2-3 原理 29 3-3實驗環境 32 3-4 實驗流程 35 3-5 數據處理 39 3-5-1最大可能性法 41 第四章 實驗結果分析與討論 44 4-1實驗可重複性 44 4-2 多波長眼內散射實驗 46 4-3 散射特性之擬合 49 4-3-1 Rayleigh Scatter權重 51 4-3-2 Mie Scatter權重 51 4-3-3 視網膜基底權重 53 4-3-4 年齡權重 54 4-3-5 擬合結果 54 4-4 實驗結果與失能眩光曲線之比較 63 第五章 結論 66 參考文獻 67 中英文名詞對照表 70

    [1] J. J. Vos, "Disability glare—a state of art report," Comm. Int. Eclairage. 39-53 (1984).
    [2] http://en.wikipedia.org/wiki/File:Schematic_diagram_of_the_human_eye_en.svg, Wikipedia.
    [3] G. Westheimer, "Image quality in the human eye," Journal of Modern Optics. 17, 641-658 (1970).
    [4] J. Goethe, Zur Farbenlehre I (Tiibingen, 1810).
    [5] W. S. Stiles, "The scattering theory of the effect of glare on the brightness difference threshold," Proc. R. Soc. Lond. (Biol.). 105, 131-141 (1929).
    [6] B. R. Wooten and G. A. Geri, "Psychophysical determination of intraocular light scatter as a function of wavelength," Vision Research. 27, 1291-1298 (1987).
    [7] T. J. T. P. van den Berg and K. E. Tan, "Light transmittance of the human cornea from 320 to 700 nm for different ages," Vision Research. 34, 1453-1456 (1994).
    [8] T. J. T. P. van den Berg, "Light scattering by donor lenses as a function of depth and wavelength," Vis. Sci. 38, 1321–1332 (1997).
    [9] T. J. T. P. van den Berg, "Importance of pathological intraocular light scatter for visual disability," Doc Ophthalmol. 61, 327-333 (1986).
    [10] J. K. Ijspeert, P. W. de Waard, T. J. T. P. van den Berg, and P. T. de Jong, "The intraocular straylight function in 129 healthy volunteers," Vision Research. 30, 699-707 (1990).
    [11] T. J. T. P. van den Berg, "Analysis of intraocular straylight, especially in relation to age," Vis. Sci. 72, 52-59 (1995).
    [12] T. J. T. P. van den Berg, J. K. Ijspeert, and P. W. de Waard, "Dependence of intraocular straylight on pigmentation and light transmission through the ocular wall," Vis. Res. 31, 1361-1367 (1991).
    [13] S. Trokel, "The physical basis for transparency of the crystalline lens," Investigative Oph thalmology. 1, 493-501 (1962).
    [14] K. O. Gilliland, C. D. Freel, S. Johnsen, W. C. Fowler, and M. Joseph Costello, "Distribution, spherical structure and predicted Mie scattering of multilamellar bodies in human age-related nuclear cataracts," Experimental Eye Research. 79, 563-576 (2004).
    [15] T. M. Aslam, D. Haider, and I. J. Murray, "Principles of disability glare measurement: an ophthalmological perspective," Acta Ophthalmologica Scandinavica. 85, 354-360 (2007).
    [16] CIE, International Lighting Vocabulary (CIE, 1987).
    [17] P. W. Cobb, "The influence of illumination of the eye on visual acuity," Am J Physiol. 29, 76-99 (1911).
    [18] R. G. D. Steel and J. H. Torrie, Principles and Procedures of Statistics (McGraw-Hill, New York, 1960).
    [19] C. M. Hill, "On choice," The American Journal of Psychology. 9, 587-590 (1898).
    [20] L. Franssen, J. E. Coppens, and T. J. T. P. van den Berg, "Compensation comparison method for assessment of retinal straylight," Investigative Ophthalmology & Visual Science. 47, 768-776 (2006).
    [21] J. E. Coppens, L. Franssen, and T. J. T. P. van den Berg, "Reliability of the compensation comparison method," J Biomed Opt. 11, 034027 (2006).
    [22] A. Cervin˜o, R. Montes-Mico, and S. L. Hosking, "Performance of the compensation comparison method for retinal straylight measurement: effect of patient''s age on repeatability," Br J Ophthalmol. 92, 788-791 (2008).
    [23] T. J. T. P. van den Berg, L. J. V. Rijn, R. Michael, C. Heine, T. Coeckelbergh, C. Nischler, H. Wilhelm, G. Grabner, M. Emesz, R. I. Barraquer, J. E. Coppens, and L. Franssen, "Straylight effects with aging and lens extraction," American Journal Of Ophthalmology. 144, 358-363 (2007).
    [24] G. C. Comficld, "Definition And Measurement Of Voltage Flicker," IEE Colloquium on Electronics in Power Systems Measurement. 54, 4/1-4 (1998).
    [25] L. O. Harvey Jr, "Efficient estimation of sensory thresholds," Behav Res Methods Instr Comp. 18, 623-632 (1986).
    [26] J. E. Coppens, L. Franssen, and T. J. T. P. van den Berg, "Wavelength dependence of intraocular straylight," Experimental Eye Research. 82, 688-692 (2006).
    [27] W. Ambach, M. Blumthaler, T. Schopf, E. Ambach, F. Katzgraber, F. Daxecker, and A. Daxer, "Spectral transmission of the optical media of the human eye with respect to keratitis and cataract formation," Doc. Ophthalmol. 88, 165-173 (1994).
    [28] J. Dillon, L. Zheng, J. C. Merriam, and E. R. Gaillard, "The optical properties of the anterior segment of the eye: Implications for cortical cataract," Exp. Eye Res. 68, 785-795 (1999).
    [29] J. ven der Kraats, Harvesting the weak angular reflections from the fundus of the human eye : on measuring and analyzing the light wasted by the retina (Utrecht University, Geneeskunde Proefschriften, 2007).
    [30] M. J. Costello, S. Johnsen, K. O. Gilliland, C. D. Freel, and W. C. Fowler, "Predicted light scattering from particles observed in human age-related nuclear cataracts using Mie scattering theory," Investigative Ophthalmology & Visual Science. 48, 303-312 (2007).
    [31] F. C. Delori and K. P. Pflibsen, "Spectral reflectance of the human ocular fundus," Applied Optics. 28, 1061-1077 (1989).
    [32] M. Hammer and D. Schweitzer, "Quantitative reflection spectroscopy at the human ocular fundus," Physics in Medicine and Biology. 47, 179-191 (2002).

    QR CODE
    :::