| 研究生: |
吳吉春 Chi-Chun Wu |
|---|---|
| 論文名稱: |
基於C-arm影像的手術導引定位 The Framework of C-arm Based Surgical Navigation |
| 指導教授: |
曾清秀
Ching-Shiow Tseng |
| 口試委員: | |
| 學位類別: |
碩士 Master |
| 系所名稱: |
工學院 - 機械工程學系 Department of Mechanical Engineering |
| 畢業學年度: | 100 |
| 語文別: | 中文 |
| 論文頁數: | 60 |
| 中文關鍵詞: | 前十字韌帶重建 、手術導引系統 、手術導引 、C-arm |
| 外文關鍵詞: | C-arm, Surgical Navigation System, ACL Reconstruction, Surgical Navigation |
| 相關次數: | 點閱:15 下載:0 |
| 分享至: |
| 查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
C-arm X光攝影機因為機動性高、取像速度快、及造影成本低等特性,是骨科手術常用的工具,但為了有效確認刀具的方位,須頻繁地拍攝以更新影像,致使病患在手術過程中承受高劑量的輻射,對醫療人員而言,長期累積的放射線劑量亦嚴重威脅身體健康,因此,如何有效減低C-arm的操作時間或使用量,並維持甚或提高手術精度,對於病患或醫療人員都是重要的考量。本研究目的在發展以C-arm影像作為手術導引與定位依據的技術,可在拍攝兩張影像的情況下,在術前由影像中相對應的成像位置計算目標點空間座標,以量測病灶的幾何尺寸,作為規劃手術的依據。手術進行過程中,可將刀具軸向即時地投影在經過畸變校正的C-arm影像上,讓醫師確認刀具與病灶的相對方位關係,達到導引定位之目的。應用此一技術建構之電腦輔助系統已於前十字韌帶重建手術中驗證其可行性與實用性。
Due to high mobility, fast imaging, and low manipulation cost, C-arm fluoroscopy is frequently used for orthopedic surgery. However, mass use of C-arm fluoroscopy for confirmation of operation results is harmful to the health of the patient and medicine persons because of accumulated dosage of radiation. In this research, we have developed image-guided stereotactic technology. Only two images are needed to determine spatial positions and orientations of the targets. A prototype of surgical navigation system has been built. The system provides the functions of preoperative planning by selecting the surgical path on the two C-arm images and intraoperative guidance by watching the difference of the preplanned and real surgical paths. This system has been also applied to preliminary clinical test of anterior cruciate ligament reconstruction (ACL Reconstruction) to verify its clinic feasibility and practicability.
[1] Allaire, G., Kaber, S.M., and K., Trabelsi, “Numerical linear algebra,” Springer, pp. 125-128, New York, NY, 2008.
[2] Barry, T.P., “Radiation exposure to an orthopedic surgeon,” Clin. Orthop., pp.182:160-163, 1993.
[3] Brack, Ch., Götte, H., Gossé, F., et al., “Toward accurate X-ray camera calibration in computer-assisted robotic surgery,” Proc. Int. Symp. Computer Assisted Radiology, pp. 721-728, Paris, 1996.
[4] Cerveri, P., Forlani, C., Borghese, N.A., et. al., “Distortion correction for x-ray image intensifiers: local unwarping polynomials and RBF neural networks,” Medical Physics, Vol. 29, Issue 8, pp. 1759-1771, 2002.
[5] Coltman, J.W., “Fluoroscopic image brightening by electronic means,” Radiology; Vol. 51, pp. 359-367, 1948.
[6] Fahrig, R., Moreau, M. and Holdsworth, D. W., “Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: correction of image intensifier distortion,” Medical Physics, Vol. 24, No. 7, pp. 1097-1106, 1997.
[7] Gonzalez, R.C., Woods, R.E., “Digital Image Processing,” 2nd ed., Prentice Hall, pp. 519-560, Upper Saddle River, NJ, 2002.
[8] Gronenschild, E., Roos, J., and Mulkens, G., “The accuracy and reproducibility of an algorithm to correct for geometric image distortion in quantitative coronary angiography,” IEEE Conference Proceedings, Computers in Cardiology, pp. 105-108, 1996.
[9] Hartley, R., and Zisserman, A., “Multiple View Geometry in Computer Vision,” 2nd ed., Cambridge University Press, pp. 153-158, 2004.
[10] Heikkila, J., Silven, O., “A four-step camera calibration procedure with implicit image correction,” IEEE Computer Society Conference on Computer Vision and Pattern Recognition, pp. 1106-1112, 1997.
[11] Hendee, W.R., and Ritenour, E.R., “Medical imaging physics,” 4th ed., Wiley-Liss, pp. 217-234, pp. 235-249, New York, NY, 2002.
[12] Hofstetter, R., Slomczykowski, M., Sati, M., et. al., “Fluoroscopy as an imaging means for computer-assisted surgical navigation,” Computer Aided Surgery, pp. 65-76, 1999.
[13] Kelley, C.T., “Iterative Methods for Linear and Nonlinear Equations,” SIAM, pp. 113-134, Philadelphia, PA, 1995.
[14] Livyatan, H., Yaniv, Z., and Joskowicz, L., “Robust automatic C-arm calibration for fluoroscopy-based navigation: a practical approach,” Proc. 5th Int. Conf. on Medical Image Computing and Computer-Aided Intervention, Vol. 2489, pp. 60-68, Tokyo, Japan, September 2002.
[15] Lo, N.N., Goh, P.S., and Khong, K.S.,“Radiation dosage from use of the image intensifier in orthopaedic surgery,” Singapore Med. J., Vol. 37, pp. 69-71, 1996.
[16] Martins, H.A., Birk, J. R. and Kelley, R.B., “Camera models based on data from two calibration planes,” Computer Graphics and Image Processing, Vol. 17, pp. 173-180, 1981.
[17] Rogers, D.F., and Adams, J.A., “Mathematical elements for computer graphics,” 2nd ed., McGraw-Hill, pp. 157-187, New York, NY, 1989.
[18] Sanders, R., Koval, K. J., DiPasquale, T., et. al., “Exposure of the orthopaedic surgeon to radiation,” J. Bone Joint Surg., 75-A, pp. 326-330, 1993.
[19] Tsai, R., “A Versatile Camera Calibration Technique for High-Accuracy 3D Machine Vision Metrology Using Off-the-Shelf TV Cameras and Lenses” IEEE Journal of Robotics and Automation, Vol. RA-3, No. 4, pp. 323-344, 1987.
[20] Wang, J., Blackburn, T.J., “The AAPM/RSNA Physics Tutorial for Residents X-ray Image Intensifiers for Fluoroscopy,” RadioGraphics, Vol. 20, Issue 5, pp. 1471-1477, 2000.
[21] Widmer, K-H., and Grützner, P.A., “Joint replacement--total hip replacement with CT-based navigation,” Injury, Vol. 35, Issue 1, Supplement 1, pp. 84-89, June 2004.
[22] Yaniv, Z., Joskowicz, L., Simkin, A., et. al., “Fluoroscopic image processing for computer-aided orthopaedic surgery,” 1st Int. Conf. on Medical Computing and Computer-Assisted Intervention, Vol. 1496, pp. 29, Boston, Massachusetts, USA, 1998.
[23] Zhang, Z. "A flexible new technique for camera calibration", IEEE Transactions on Pattern Analysis and Machine Intelligence, Vol. 22, No. 11, pp. 1330-1334, 2000.